T4 Endonuclease VII
$0.00 – $714.00
SKU | Volumes | Concentration | Price | Quantity | ||
---|---|---|---|---|---|---|
ENDO7-100 | 2,500 U | 10,000 U/ml | $238.00 | |||
ENDO7-200 | 10,000 U | 10,000 U/ml | $714.00 | |||
ENDO7-OEM | T4 Endonuclease VII | Please inquire |
- Description
- Additional information
- Documents
- Q&A
Description
Description:
Endonuclease VII is the product of gene 49 of bacteriophage T4. It has a mass of 18 kDa. T4 Endonuclease VII involves in DNA-packaging, genetic recombination and mismatch repair in vivo. It has also been demonstrated in vitro to resolve single-base misparings, heteroduplex loops and branched DNAs, such as four-way Holliday junctions and three-way Y-structures.
Source:
A recombinant E. coli strain carrying the cloned T4 Endonuclease VII gene
Unit Definition:
One unit (0.5 ng) of the enzyme resolves 50% of 1 pmol FAM labeled 28mer oligonucleotide substrate [1] within the immobile 4-way Holliday junction structure in 30 minutes at 37°C in 50mM Tris-HCl, pH 8.0, 10mM MgCl2, 10mM 2-ME and 0.1 μg/μl BSA.
Specific Activity:
2000 U/µg
Recommended Storage Condition:
-20°C
Experimental Data:
Figure1. Performance of MCLAB’s T4 Endonuclease VII analyzed by capillary electrophoresis. (a) Negative control sample analysis, 10 pmol of FAM labeled 28mer oligonucleotide substrate. (b) 40 U of MCLAB’s T4 Endonuclease VII was able to fully resolve 10 pmol of FAM labeled 28mer oligonucleotide substrate with a 4-way Holliday junction structure (30 minutes at 37°C in 50 mM Tris-HCl, pH 8.0, 10 mM MgCl2, 10 mM 2-ME and 0.1 μg/μl BSA).
Figure2. MCLAB’s T4 Endonuclease VII and T7 Endonuclease I (from other supplier) activity comparison. (a) 10 U (275 fmol) of MCLAB T4’s Endonuclease VII can resolve 64% of 10 pmol of 4-way junction substrate (enzyme to substrate molar ratio 1:70) in 30 minutes at 37°C in 50 mM Tris-HCl, pH 8.0, 10 mM MgCl2, 10 mM 2-ME and 0.1 μg/μl BSA. (b) 40 U (368 fmol) of T7 Endonuclease I (supplier N) only resolves 43% of 10 pmol of 4-way junction substrate (enzyme to substrate molar ratio 1:50) in 30 minutes at 37°C in 50 mM NaCl, 10 mM Tris-HCl, pH 7.9, 10 mM MgCl2, 1 mM DTT. Compared to T7 Endonuclease I (supplier N), MCLAB’s T4 Endonuclease VII resolves 4-way Holliday Junctions at a higher yield in 30 minutes with less enzyme.
T4 Endonuclease VII Protocol
For 4-way junction substrate:
1. Prepare the following reaction:
Component |
Volume |
Water |
16 µl |
10x Endo VII reaction buffer |
2 µl |
10µM 4-way Junction (FAM labeled) |
1 µl |
Endo VII (dilute if necessary) |
1 µl |
Total |
20 µl |
2. Mix well and incubate the reaction @ 37°C for 30min.
3. Use 1 µl reaction to analyze the cleaved fragments on Capillary electrophoresis.
For single base mismatch substrate:
1. Use about 200-400ng DNA fragment that contains single base mismatch for each reaction:
Component | Volume |
10x Endo VII buffer | 1 µl |
Substrate | 200-400ng |
Endo VII enzyme (dilute if necessary) | 1 µl |
Water | To total volume of 10 µl |
Total | 10 µl |
2. Mix well and incubate the reaction @ 37°C for 30min.
3. Run a 2% agarose gel and check for cleaved bands.
Table. Comparison of T4 Endonuclease VII and T7 Endonuclease I
T4 Endonuclease VII |
T7 Endonuclease I |
|
Protein Mass |
18 KDa | 60 kDa |
Function |
Resolvase | Resolvase |
Application |
Enzymatic mutation detection Resolve branched DNA Detect or cleave heteroduplexes |
Enzymatic mutation detection Resolve branched DNA Detect or cleave heteroduplexes |
Source |
Bacteriophage T4 | Bacteriophage T7 |
Protein Design |
T4 Endonuclease VII | A fusion of maltose binding protein (MBP) and T7 Endonuclease I |
Activity |
High* 10 units of the enzyme (278 fmol protein, molar ratio 1:70 (Enzyme:Substrate)) resolve 64% of 4-way Junctions. |
Low* 40 units of the enzyme (368 fmol protein, molar ratio 1:50 (Enzyme:Substrate)) resolve 43% of 4-way Junctions. |
Specificity |
High* (single resolved peak shown on CE) | Low* (multiple resolved peaks shown on CE) |
* See Figure 2 for T4 endonuclease VII and T7 endonuclease I activity comparison result.
Supplied in:
10 mM Tris-HCl
50 mM KCl
1 mM DTT
0.1 mM EDTA
50% Glycerol
pH 7.4 @ 25°C
Supplied With:
10x T4 Endonuclease VII Reaction Buffer:
500 mM Tris-HCl
100 mM MgCl2
100 mM 2-mercaptoethanol
1 mg/ml BSA
pH 8.0 @ 25°C
Reference:
1. Golz, S., Birkenbihl, R. P., and Kemper, B. (1995), DNA Research 2, 277-284.
Additional information
OPTIONS | 2,500 U (10,000 U/ml), 10,000 U (10,000 U/ml), T4 Endonuclease VII |
---|
Manual & Protocols
COA ( Certificate of Analysis )
MSDS & Certificates
The Q&A for this product will be available soon.